• Archives

  • Categories

  • Pages

How do I start up my aeration system for the spring?| Ponds & Lakes Q&A

Q: My pond has some filamentous algae growth around the edges. It’s too cold to treat, right?

Q: How do I start up my aeration system for the spring?

Molly – Provo, UT

A: If your Airmax® Aeration System has been sitting idle for the past four months, it’s about time to get that thing cranking again. Here’s a seven-step checklist to follow when air and water temperatures start heating up this spring.

  1. Change Your Air Filter: Your air filter, which prevents debris from entering your air compressor, can be cleaned periodically to remove light debris – but it should be replaced every three to six months for maximum system performance and longevity.
  2. Check, Clean Side Intake Air Filters: Take a look at your side intake air filters on your cabinet, too, and make sure they’re clean and unobstructed.
  3. Ensure Cabinet Fan Works: To make sure fresh air will tunnel evenly through your cabinet, flip on your fan and verify that it’s working properly.
  4. Purge Membrane Diffuser Sticks: Though they’re virtually maintenance-free, these diffuser sticks, which deliver the air bubbles to the water, should be purged and inspected before they’re submerged.
  5. Airlines Cleared: It could still be icy in your pond, so check your airlines for ice buildup. To clear them, pour 1 cup of isopropyl alcohol through the airline running out to each plate, turn on the compressor and push through the line to free any tiny icebergs.
  6. Start Your Engines – Gradually: To prevent shocking your pond, follow your aeration system’s initial seven-day startup procedure. On Day 1, run the system for 30 minutes and then turn it off for the rest of the day. On each day following, double the time: Day 2, run for one hour; Day 3, run for two hours; Day 4, run for four hours; and so on. On Day 7, begin running it for 24 hours a day, seven days a week.
  7. Pressure Check: Once your system is up and running, make sure that its pressure gauge stays within the normal range of 5 to 10 psi. An easy way to do this to mark the gauge upon initial start up and check it regularly to verify pressure has not significantly risen above or dropped below your initial reading.

Following these simple steps will guarantee a smooth start to aerating your pond this spring. If you’re ever in doubt, check out your owner’s manual or contact one of the experts at The Pond Guy®.

Pond Talk: Are you planning to add any fish or plants to your pond this spring?

Protect and Shade Your Pond- Pond Logic(r) Pond Dye

I think my aeration airline is clogged or frozen. What should I do? | Ponds & Lakes Q&A

Q: I think my aeration airline is clogged or frozen. What should I do?

Q: I think my aeration airline is clogged or frozen. What should I do?

Ben – Franklin, PA

A: We all know how important an aeration system is in your pond or lake – but it doesn’t do much good if your airline is clogged or frozen! If you don’t see bubbles at the surface and your compressor is running, here’s what we recommend to troubleshoot a closed line:

  1. Gauge Check: First of all, check your air pressure gauge. Is it reading higher than normal? If so, your compressor is struggling to push the air through the blockage, which is creating increased pressure in the line.
  2. System Check: Next, disconnect the airline at the compressor and check to see whether air is coming out. If it is, your compressor works just fine – but your airline might have ice blockages. To melt them and open the flow back up, pour 1 cup of isopropyl alcohol through each airline (or the airline you believe is clogged or frozen).
  3. Maintenance Check: If no air is coming out of your compressor, you might need to do some maintenance on it. Over time, seals and moving parts will wear and break down, causing decreased system performance. The Pond Logic® SilentAir™ Piston Compressor Maintenance Kits include a range of washers, gaskets and hardware that will get your compressor humming again.
  4. Air Filter Check: While you’re doing maintenance on your air compressor, it’s a good idea to check your air filter, too. If it’s full of gunk and debris, consider replacing it with the SilentAir™ RP Series Compressor Air Filters. They’re designed to be replaced every three to six months for maximum system performance and longevity.

Pond Talk: Have you had a lot of trouble with frozen airlines this winter?

Maximize System Performance & Longevity- Airmax(r) SilentAir(tm) RP Series Compressor Air Filters